A Global Study Comparing Pulsed Field Ablation With Electrographic Flow Mapping Versus Posterior Wall Ablation for Persistent Atrial Fibrillation

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorBoston Scientific Corporation

About this trial

The purpose of this study is to establish the safety of the pulsed field ablation (PFA) therapy of Pulmonary Veins and Electrographic Flow (EGF) identified extra-PV sources of atrial fibrillation (PVI + EGF ablation of sources) and to demonstrate its non-inferiority in effectiveness compared to PFA of Pulmonary Veins and LA Posterior Wall (PVI+ PWA) in the treatment of de novo symptomatic drug-refractory persistent atrial fibrillation (PersAF).

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

≥ 18 years of age, or older if required by local law

Documentation, such as physician note, of persistent continuous AF for > 7 days and ≤ 365 days and the arrhythmia symptoms

A 24-hour continuous ECG recording confirming continuous AF or

Two (2) ECGs (from any regulatory cleared rhythm monitoring device) showing continuous AF taken at least 7 days apart

Disqualifiers

Left atrial anteroposterior diameter ≥ 5.5 cm, or if1 LA diameter not available, non-indexed volume >100 ml (physician note or imaging)

Any prior left atrial ablation

Any prior atrial surgery

Current atrial myxoma

Trial design

Design model

Parallel

Treatments tested in this trial

  • FARAPOINT Pulsed Field Ablation System

    Device

    A component of the FARAPULSE Pulsed Field Ablation (PFA) System and is a multi-electrode bidirectional, deflectable percutaneous catheter, an adjunctive catheter designed to create focal-type lesions for the creation of an ablation line between the inferior vena cava and the tricuspid valve.

  • OptiMap System (non-ablative)

    Device

    An electrophysiology mapping system that uses a proprietary algorithm to analyze electrogram signals.

  • FARAPULSE Pulsed Field Ablation (PFA) System and Opal HDx Mapping System

    Device

    All subjects will undergo electroanatomical mapping of the entire left atrium with the FARAWAVE NAV Catheter and Opal HDx Mapping System, followed by PFA PVI with the FARAWAVE NAV PFA Catheter, per the instructions of use.

Treatment groups

699 Participants
are divided into 2 treatment groups
Group A: Control ArmActive comparator 2 interventions
Group B: Treatment ArmExperimental treatment 3 interventions

Trial outcomes

Primary outcomes

1

Primary Safety Endpoint

The primary safety endpoint is the rate of ITT subjects in the PVI+EGF arm with one or more of the following serious device- or procedure-related Composite Adverse Events (CAEs) assessed through 60 days following the Index Procedure.

Time frame
60 Days
2

Primary Effectiveness Endpoint

The primary effectiveness endpoint is the rate of ITT subjects with treatment success in the PVI+EGF arm vs. the PVI+PWA control arm through Day 365, aiming to demonstrate non-inferiority of PVI+EGF compared to the PVI+PWA control.

Time frame
365 Days

Secondary outcomes

1

Secondary Effectiveness Endpoint

The secondary effectiveness endpoint is a test for superiority in Treatment Success between the Treatment Arm and the Control Arm. The test for superiority will only be conducted if the non-inferiority test for the PEE is passed and the result favors the Treatment Arm.

Time frame
365 Days

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.