A Study of Assessment on Safety and Effectiveness of BWI Pulsed Field Ablation With OMNYPULSE Catheter for the Treatment of Paroxysmal Atrial Fibrillation (PAF)

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-80
SponsorBiosense Webster, Inc.

About this trial

The purpose of this study is to demonstrate the safety and 12-month effectiveness of the BWI OMNYPULSE™ pulsed field ablation (PFA) platform for pulmonary vein isolation (PVI) in the treatment of participants with symptomatic paroxysmal atrial fibrillation (PAF), an irregular heart rate that causes abnormal blood flow.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

At least two symptomatic AF episodes within last six months from enrollment

At least one electrocardiographically documented AF episode within twelve months prior to enrollment

Failed at least one Class I or Class III antiarrhythmic drug

Willing and capable to provide consent

Disqualifiers

Previously diagnosed with persistent AF (greater than [>] 7 days in duration)

AF secondary to electrolyte imbalance, thyroid disease, or reversible or non-cardiac cause.

Previous surgical or catheter ablation for AF

Patients known to require ablation outside the PV ostia and outside the CTI region.

Trial design

Design model

Single group

Treatments tested in this trial

  • OMNYPULSE™ Catheter with the TRUPULSE Generator

    Device

    OMNYPULSE™ Catheter and TRUPULSE™ Generator will be used for PF ablation.

Treatment groups

440 Participants
are divided into 1 treatment group
Group A: Pulsed Field (PF) Ablation SystemExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Number of Participants with Primary Adverse Events (PAEs)

Number of participants with PAEs (within 7 days following the ablation procedure unless otherwise indicated) will be reported. PAEs will include the following adverse events: esophageal perforating complications (atrio-esophageal fistula, esophago-pericardial fistula), phrenic nerve paralysis (permanent), cardiac tamponade/perforation, pulmonary vein stenosis (PVS), device or procedure related death, stroke/cerebrovascular accident (CVA), major vascular access complication/bleeding, thromboembolism, myocardial infarction, transient ischemic attack (TIA), pericarditis, heart block, pulmonary edema (respiratory insufficiency) and vagal nerve injury/gastroparesis.

Time frame
7 days post-procedure
2

Number of Participants Reporting Freedom from Documented (Symptomatic and Asymptomatic) Atrial Tachyarrhythmia (Atrial Fibrillation [AF], Atrial Tachycardia [AT] or Atrial Flutter [AFL] of Unknown Origin) Episodes

Number of participants reporting freedom from documented (symptomatic and asymptomatic) atrial tachyarrhythmia (AF, AT, or AFL of unknown origin) episodes of \>= 30 seconds based on sponsor provided transtelephonic monitoring (TTM) or holter device or continuous on standard 12-lead electrocardiogram (ECG) data during the effectiveness evaluation period will be reported.

Time frame
Day 91 to Day 365 post-procedure

Secondary outcomes

1

Change from Baseline in Atrial Fibrillation Effect on Quality of Life (AFEQT) Total Score

The AFEQT uses a questionnaire to evaluate symptoms, daily activities and treatment concerns participants have related to atrial fibrillation. An overall AFEQT score ranges from 0 to 100. A score of 0 corresponds to complete disability (or responding "extremely" difficult to all questions answered), while a score of 100 corresponds to no disability (or responding "not at all" limited, difficult or bothersome to all questions answered). A positive change in score corresponds to improvement in AF symptoms.

Time frame
Baseline, Month 12

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.