About this trial
The goal of this physiological intervention study is to unravel the (patho)physiological mechanisms and potential clinical benefits of a pre-specified early switch from controlled to assisted ventilation in mechanically ventilated adult patients with acute hypoxemic respiratory failure (PaO2/FiO2 ratio \< 200 mmHg).
The intervention is that participants will be switched from controlled to assisted ventilation when PaO2/FiO2 ratio \> 200 mmHg.
The primary endpoint is the change in regional lung stress (as derived by electrical impedance tomography) when switching from controlled to assisted ventilation and until a successful or failed switch.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
18 years old
Written informed consent from a legal representative
Mechanical ventilation via an endotracheal tube
Acute hypoxemic respiratory failure with PaO2/FiO2 ratio < 200 mmHg
Disqualifiers
Expected mechanical ventilation duration of <48 hours
Pure chronic obstructive pulmonary disease exacerbation
Pre-existent respiratory muscle disease
Contraindication to EIT monitoring (as per clinical protocol, e.g. pacemaker, burns or thoracic wounds limiting electrode placement)
Trial design
Single group
Treatments tested in this trial
Pre-specified switch from controlled to assisted ventilation when PaO2/FiO2-ratio > 200 mmHg
Other interventionA pre-specified switch from controlled to assisted ventilation will be initiated when PaO2/FiO2-ratio \> 200 mmHg. The moment of switch is pre-specified but patient management and ventilator settings are up to the clinical team. Switch is complete when the patient triggers all breaths spontaneously. Switch success is defined if patient reaches 72 hours on assisted ventilation. Switch failure is defined if patient switches back to controlled ventilation for more than 2 hours before 72 hours.
Treatment groups
Trial outcomes
Primary outcomes
Regional lung stress
The change in regional lung stress as derived from EIT recordings by computing the regional ventilation distribution (ventral-to-dorsal ratio).
Secondary outcomes
Electrical Impedance Tomography (EIT) parameters
Change in EIT parameters after transition from controlled to assisted ventilation (%)
Photon-Counting Computed Tomography (PCCT)-derived ventilation/perfusion mismatch
Ventilation/perfusion mismatch during controlled ventilation measured with photon-counting CT scan
Electrical Impedance Tomography (EIT)-derived ventilation/perfusion mismatch
Ventilation/perfusion mismatch during controlled ventilation measured with EIT
Respiratory mechanics
Change in respiratory mechanics after transition from controlled to assisted ventilation (cmH2O)