About this trial
The goal of this clinical trial is to learn whether a powered wearable lower-limb exoskeleton can improve walking performance in independently ambulatory older adults aged 65 to 75 years.
The main questions it aims to answer are:
* Does use of a powered lower-limb exoskeleton increase comfortable walking speed over 10 meters? * Does use of a powered lower-limb exoskeleton increase average walking speed during a 400-meter walk?
Researchers will compare walking performance in older adults during walking with the powered exoskeleton and walking without the device to determine whether the exoskeleton improves mobility. Young-adult reference participants will also complete walking assessments to provide reference values for walking performance.
Participants will:
* Attend a screening and familiarization visit. * Complete walking assessments with and without the powered exoskeleton in randomized order (older adults only). * Perform a 10-meter walk test, a 400-meter walk test, and other physical performance assessments. * Complete questionnaires about balance confidence, fear of falling, and device usability. * Be monitored for safety events during testing.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Older adults aged 65 to 75 years who are community-dwelling, independently ambulatory, able to walk independently on level ground, able to maintain standing balance without personal assistance, and able to understand study instructions.
Young-adult reference participants aged 18 to 22 years who are healthy university students without known conditions affecting walking or balance.
Disqualifiers
Self-reported neurological disease affecting gait or balance.
Major musculoskeletal injury or surgery affecting walking within the previous 6 months.
Uncontrolled cardiopulmonary disease.
Severe visual or vestibular impairment affecting safe walking.
Trial design
Crossover
Treatments tested in this trial
Powered Lower-Limb Exoskeleton
DeviceA commercially available powered wearable lower-limb exoskeleton (VIATRIX; ULS Robotics Co., Ltd., Shanghai, China) designed to provide bilateral lower-limb assistance during walking. The device is worn around the pelvis and lower limbs and provides powered assistance through bilateral actuation. During powered-device assessments, participants use the adaptive assistive walking mode following device fitting and familiarization procedures.
Treatment groups
Trial outcomes
Primary outcomes
10-Meter Comfortable Gait Speed
Comfortable gait speed (m/s) measured during a 10-meter walk test. Participants walk at their usual comfortable speed along a flat indoor walkway. Two trials are completed, and the mean gait speed is used for analysis.
400-Meter Average Walking Speed
Average walking speed (m/s) measured during a 400-meter walk test. Participants walk 400 meters at a self-selected comfortable speed on an indoor walkway. Average walking speed is calculated as total walking distance divided by total completion time.
Secondary outcomes
Short Physical Performance Battery Score
Lower-extremity physical performance assessed using the Short Physical Performance Battery. The test includes standing balance, short-distance gait speed, and repeated chair-stand performance. Component scores are summed to produce a total score ranging from 0 to 12, with higher scores indicating better physical performance.
Mean Heart Rate During the 400-Meter Walk
Mean heart rate recorded continuously during the 400-meter walk test using a wrist-worn optical heart-rate monitor.
Borg Rating of Perceived Exertion
Perceived exertion is assessed immediately after the 400-meter walk test using the Borg Rating of Perceived Exertion Scale. Scores range from 6 to 20, where 6 indicates "no exertion at all" and 20 indicates "maximal exertion." Higher scores indicate greater perceived exertion and a worse outcome.
Fear of Falling 10-Rating Scale Score
Immediate fear of falling will be assessed after each trial condition using the single-item Fear of Falling 10-Point Rating Scale. Participants will rate how concerned they were about falling during the walking and physical performance tests completed during that visit. Scores range from 0 to 10, where 0 indicates "not concerned at all" and 10 indicates "extremely concerned." Higher scores indicate greater fear of falling and a worse outcome.
Other outcomes
Number of Falls
Number of falls occurring during study procedures. A fall is defined as an event in which the participant comes to rest inadvertently on the ground, floor, or another lower level.
Number of Near-Loss-of-Balance Events
Number of near-loss-of-balance events occurring during study procedures. A near-loss-of-balance event is defined as an observable unintended balance disturbance requiring a corrective response to prevent a fall.
Number of Device-Related Adverse Events
Number of adverse events judged to be caused by, probably caused by, or associated with use of the powered lower-limb exoskeleton.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.