[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-studies-list:{\"overallStatus\":[\"RECRUITING\",\"AVAILABLE\",\"NOT_YET_RECRUITING\"],\"leadSponsorName\":\"Jonathon Myers\",\"orderBy\":\"LastUpdateSubmitDate:desc\",\"size\":25,\"offset\":0}":3,"health-study-condition:":44},{"pageToken":4,"total":5,"offset":6,"count":5,"results":7},null,1,0,[8],{"id":9,"slug":4,"hasResults":10,"nctId":11,"briefTitle":12,"officialTitle":13,"acronym":14,"eligibilityCriteria":15,"healthyVolunteers":10,"sex":16,"minAge":17,"maxAge":4,"enrollmentInfo":18,"targetDuration":4,"studyType":21,"phases":22,"briefSummary":24,"conditions":25,"keywords":29,"overallStatus":32,"whyStopped":4,"lastUpdateSubmitDate":33,"lastUpdatePostDateStruct":34,"startDateStruct":37,"completionDateStruct":39,"leadSponsor":41,"locationsCount":5},"100610487",false,"NCT07228221","Standalone iStent Infinite and iDose TR for Management of Moderate to Severe Open Angle Glaucoma","iStent Infinite and iDose TR for Management of Moderate to Severe Primary Open Angle Glaucoma Are a Safe and Effective Alternative to Filtering Surgery for IOP Reduction in Patients With Medically Uncontrolled Glaucoma. (POAG)","POAG","Inclusion Criteria:\n\n* Moderate to severe open angle glaucoma (including POAG, PG, and PXG)\n* Open angle configuration (Shaffer grade ≥ 3), normal angle anatomy9\n* Visual acuity HM or better\n* VF MD -6dB or worse\n* Failed medical therapy and\u002For laser treatment\n* Incisional glaucoma surgery contemplated as next intervention\n* Phakic or pseudophakic\n\nExclusion Criteria:\n\n* Traumatic, uveitic, neovascular glaucoma, or angle closure glaucoma\n* Previous incisional glaucoma surgery\n* ALT; History of iridotomy, SLT, or micropulse laser trabeculoplasty within the prior 90 days\n* Active ocular inflammation or edema, clinically significant corneal dystrophy\n* Corneal or other pathology preventing accurate Goldmann applanation tonometry","ALL","18 Years",{"count":19,"type":20},20,"ESTIMATED","INTERVENTIONAL",[23],"PHASE4","The Investigators will investigate the efficacy of combining the standalone iStent infinite and iDose that are minimally invasive surgical and drug depot options are a safe and effective alternative to filtering surgery for intraocuar pressure reduction in patients with medically uncontrolled open angle glaucoma.",[26,27,28],"Open Angle Glaucoma","Pigmentary Glaucoma","Pseudoexfoliation Glaucoma",[14,30,31],"PG","PXG","RECRUITING","2025-11-13",{"date":35,"type":36},"2025-11-14","ACTUAL",{"date":38,"type":20},"2026-01-05",{"date":40,"type":20},"2031-12-31",{"name":42,"class":43},"Jonathon Myers","OTHER",""]